properstable temperature in the process of mold forming so as to guarantee high quality of products and raise the
productive efficiency.
Parameters:
Model | Temp | Heat capacity | Pump power | Max. pump volume | Max. pressure of pump | Liquid Storage Quantity | Cooling method | Mold connecting | External size | Weight |
|
| Kw | Kw | L/min | bar | L |
|
| mm | Kg |
SR-6-W(2D) | 95 | 6+6 | 0.37 × 2 | 40 | 1.5 | 10x2 | indirect cooling | 3/8" x 4 | 1000 x 450 x 850 | 120 |
SR-6-0(2D) | 170 | 6+6 | 0.37x2 | 40 | 1.5 | 10x2 | 3/8" x 4 | 1000 x 450x850 | 120 | |
SR-9-W(2D) | 95 | 9+9 | 0.75 x 2 | 100 | 2 | 10x2 | 3/8" x 8 | 950 x 700x750 | 140 | |
SR-9-O(2D) | 170 | 9+9 | 0.75 x 2 | 100 | 2 | 10x2 | 3/8" x 8 | 950 x 700x750 | 140 | |
SR-12-W(2D) | 95 | 12+12 | 0.75 x 2 | 110 | 2.2 | 10x2 | 3/8" x 8 | 950 x 700x750 | 140 | |
SR-12-0(2D) | 170 | 12+12 | 0.75 x 2 | 110 | 2.2 | 10x2 | 3/8" x 8 | 950 x 700x750 | 140 |